Products
Delta Inverter Vfd 0.75~630KW Variable Frequency Inverter AC Drive
Delta Inverter Vfd 0.75~630KW Variable Frequency Inverter AC Drive
Delta Inverter Vfd 0.75~630KW Variable Frequency Inverter AC Drive
Delta Inverter Vfd 0.75~630KW Variable Frequency Inverter AC Drive
Delta Inverter Vfd 0.75~630KW Variable Frequency Inverter AC Drive
Delta Inverter Vfd 0.75~630KW Variable Frequency Inverter AC Drive
Delta Inverter Vfd 0.75~630KW Variable Frequency Inverter AC Drive
Delta Inverter Vfd 0.75~630KW Variable Frequency Inverter AC Drive

Delta Inverter Vfd 0.75~630KW Variable Frequency Inverter AC Drive

FOB Reference Price: Get Latest Price
≥1 Pieces
US $240
≥10 Pieces
US $215
≥50 Pieces
US $210
Free Inquiry
Customized Request
Contact us For product pricing, customization, or other inquiries:
Contact Us
  • Product Details
  • {{item.text}}

Quick Details

Rated Output Current (A):
5-346A
Applicable Motor Output (kW):
0.75-90
Product name:
Power Inverter
Warranty:
1 Year
Drive Weight (Kg):
2.6±0.3~86.5±1.5
EMC Filter:
Optional
Cooling Method:
Natural/Fan cooling
Power Factor:
> 0.98
Frequency Tolerance:
47 ~ 63 Hz

Quick Details

Output Current:
5-346A
Place of Origin:
China
Rated Output Capacity (kVA):
2.0-138kVA
Rated Output Current (A):
5-346A
Applicable Motor Output (kW):
0.75-90
Product name:
Power Inverter
Warranty:
1 Year
Drive Weight (Kg):
2.6±0.3~86.5±1.5
EMC Filter:
Optional
Cooling Method:
Natural/Fan cooling
Power Factor:
> 0.98
Frequency Tolerance:
47 ~ 63 Hz
Related Products

Where to find full ranges of Servo Motors and Drivers?

VFD C2000 Series

VFD CP2000 Series

VFD MS300 Series

Product Description
Why choose Delta?




>>How to choose Delta VFD?

>>What are the features of C2000 VFD?


>> How is the efficiency of C2000 Series?
Control Characteristics
Control Method
Pulse Width Modulated (PWM)
Control Mode
230 V / 460 V model:

1: V / F,2: SVC,3: VF+PG,4: FOC+PG,5: TQC+PG,6: PM+PG,7: FOC sensorless,8: TQC sensorless,

9: PM sensorless
575 V / 690 V model:

1: V / F,2: V / F+PG,3: SVC
Starting Torque
Reach up to 150% or above at 0.5 Hz. Under FOC+PG mode, starting torque can reach 150% at 0 Hz
V / F Curve
4-point adjustable V / F curve and square curve
Speed Response Ability
5 Hz (vector control can reach up to 40 Hz)
Torque Limit
230 V / 460 V model: Normal duty 160%, heavy duty 180% of torque current;

575 V / 690 V model: Maximum 200% of torque current
Torque Accuracy at TQC Mode
TQC + PG:±5%

TQC Sensorless:±15%
Max. Output Frequency (Hz)
Light Duty / Normal duty: 0.01 ~ 599.00 Hz; Heavy duty: 0.00 ~ 300.00 Hz
Frequency Output Accuracy
Digital command: ±0.01%, -10 ° C ~ +40 ° C, Analog command: ±0.1%, 25 ±10 ° C
Output Frequency Resolution
Digital command: 0.01 Hz, Analog command: 0.03 * max. output frequency / 60 Hz (±11 bit)
Overload Capacity
230 V / 460 V model:

Normal duty: 120% of rated current can endure for 1 minute during every 5 minutes ;

160% of rated current can endure for 3 seconds during every 30 seconds

Heavy duty: 150% of rated current can endure for 1 minute during every 5 minutes ;

180% of rated current can endure for 3 seconds during every 30 seconds
575 V / 690 V model:

Light duty: 120% of rated current can endure for 1 minute

Normal duty: 120% of rated current can endure for 1 minute, 150% can endure for 3 seconds

Heavy duty: 150% of rated current can endure for 1 minute, 180% can endure for 3 seconds
Frequency Setting Signal
+10 V ~ -10V, 0 ~ +10 V, 4 ~ 20 mA, 0 ~ 20 mA, pulse input
Accel. / decel. Time
0.00 ~ 600.00 / 0.0 ~ 6000.0 Seconds
Main Control Function
Torque control, Speed / torque control switching, Feed forward control, Zero-servo control,

Momentary power loss ride thru, Speed search, Over-torque detection, Torque Limit, 16-step speed (Max.),

Accel / decel time switch, S-curve accel / decel, 3-wire sequence, Auto-Tuning (rotational, stationary), Dwell,

Slip compensation, Torque compensation, JOG frequency, Fault restart,

Frequency upper / lower limit settings, DC injection braking at start / stop, High slip braking, Parameter copy

PID control (with sleep function), Energy saving control, MODOBUS communication (RS-485 RJ45, Max.

115.2 kbps)
Fan Control
230 V model:

VFD150C23A (include) and series above: PMW control; VFD110C23A and below: on / off switch control

460 V model:

VFD185C43A (include) and series above: PMW control; VFD150C43A and below: on / off switch control

575 V / 690 V model: PWM control



>>How big is a Delta C2000?



>>How can I identify my model?



>>WHY CP2000?

>>How can CP2000 apply for Water Circulation Pump Control?




>>What are the features of CP2000?




>> How to choose CP2000 Series?



>> How is the efficiency of C2000 Series?

Control Method
Pulse Width Modulated (PWM)
Control Mode
230 V / 460 V model:

1: V / F (V / F control), 2: SVC (Sensorless Vector Control), 3: PM (Permanent Magnet Motor)

575 V / 690 V model:

1: V / F,2: SVC
Starting Torque
Reach up to 150% or above at 0.5 Hz
V / F Curve
4 point adjustable V / F curve and square curve
Speed Response Ability
5 Hz
Torque Limit
Light Duty: Max. 130% torque current; Normal Duty: Max. 160% torque current
Torque Accuracy
±5%
Max. Output Frequency (Hz)
230 V model: 599.00 (55 kW and above: 400.00)

460 V model: 599.00 (90 kW and above: 400.00)

575 V / 690 V model: 599.00
Frequency Output Accuracy
Digital command: ±0.01%, -10 °C ~ +40 °C, Analog command: ±0.1%, 25 ±10 °C
Output Frequency Resolution
Digital command: 0.01 Hz; Analog command: Max. output frequency x 0.03 / 60 Hz (±11 bit)
Overload Tolerance
Light duty: 120% of rated current for 1 minute during every 5 minutes

Normal duty: 120% of rated current for 1 minute during every 5 minutes;160% of rated current for 3 seconds during every 25 seconds
Frequency Setting Signal
0 ~ +10 V, 4 ~ 20 mA, 0 ~ 20 mA
Accel. / decel. Time
0.00 ~ 600.00 / 0.0 ~ 6000.0 seconds
Main Control Function
Fault restart, Torque limit, High-Slip braking, Dwell, 3-wire sequence, Speed search, Parameter copy, JOG frequency, Slip compensation, Torque compensation, S-curve accel / decel, Energy saving control, Accel / Decel. Time
switch, Frequency upper / lower limit settings, Momentary power loss ride thru, PID control (with sleep function), Auto-Tuning (rotational, stationary), DC injection braking at start / stop, BACnet Communication, 17-step speed (max.), Over-torque detection MODBUS communication (RS-485 RJ45, Max. 5.2 Kbps)
Fan Control
230 V model: Model with spec higher than VFD185CP23 (included) are PWM control;
Model with spec lower than VFD150CP23 (not included) are on / off switch control.
460 V model: Model with spec higher than VFD220CP43/4E (included) are PWM control; Model with spec lower than VFD185CP43/4E (not included) are on / off switch control.
575 V / 690 V model: PWM control



>>How big is a Delta CP2000?


>>How can I identify my models?


>> What are the applications of MS300?


>>How to choose MS300 Series?



>> How is the efficiency of MS300 Series?

Control

Functions
Control Methods
V/F, SVC
Applicant Motors
Induction Motor (IM), Interior Permanent Magnet (IPM) Motor, Surface Permanent Magnet (SPM) Motor
Max. Output

Frequency
Standard model: 599.00 Hz ; High speed model: 1500.0 Hz (with derating, V/F control only)
Starting Torque*
150% / 3 Hz (V/f, SVC control for IM, heavy duty)

100% / (1/20 of motor rated frequency) (SVC control for PM, heavy duty)
Speed Control

Range*
1 : 50 (V/f, SVC control for IM, heavy duty)

1 : 20 (SVC control for PM, heavy duty )
Overload

Tolerance
Normal Duty (ND): 120% of rated output current for 60 seconds; 150% of rated output current for 3 seconds

Heavy Duty (HD): 150% of rated output current for 60 seconds; 200% of rated output current for 3 seconds
Frequency

Setting Signal
0 ~ +10 V / -10 V ~ +10 V, 4 ~ 20 mA / 0 ~ +10 V, 1 pulse input (33 kHz), 1 pulse output (33 kHz)
Main Control

Functions
Multiple motor switches (max. 4 independent motor parameter settings), fast run,

deceleration energy back (DEB) function, wobble frequency function, fast deceleration function,

master and auxiliary frequency source selectable, momentary power loss ride thru, speed search, over-torque detection,

16-step speed (max.), accel/decel time switch, S-curve accel/decel, 3-wire sequence, JOG frequency,

upper/lower limits for frequency reference, DC injection braking at start and stop, PID control, built-in PLC (2k steps),

simple positioning function, MODBUS is integrated as standard



>> How big is MS300?


>> How many models do Delta VFD have?
Packing & Delivery
Our Company

Full Ranges of


Delta Component


IN Stock NOW !




Our Service
FAQ
WhatsApp