| Technical parameters | |
| model | S10 |
| pH | |
| Measuring range | -2.000 ~ 20.000pH |
| measurement accuracy | ± 0.002pH |
| display resolution | 0.001, 0.01, 0.1pH, optional |
| Calibration point | 1 ~ 5 o'clock |
| pH buffering options | USA, NIST, DIN, custom |
| mV | |
| Measuring range | ± 1999.9mV |
| measurement accuracy | ± 0.2mV |
| display resolution | 0.1, 1mV, optional |
| Calibration point | 1 o'clock |
| Measurement mode | Relative or absolute mV |
| Ion concentration | |
| Measuring range | 0.001 ~ 19999 (depending on the range of the ion selective electrode) |
| measurement accuracy | ± 0.5% F.S (mono-ion), ± 1% F.S (di-ion) |
| display resolution | 0.001, 0.01, 0.1, 1 |
| Calibration point | 2 ~ 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
| Units of measurement | ppm, mg / L, mol / L, mmol / L |
| Conductivity | |
| Measuring range | 0.01 ~ 20.00, 200.0, 2000µS / cm, 20.00, 200.0mS / cm |
| measurement accuracy | ± 0.5% F.S |
| display resolution | 0.001, 0.01, 0.1, 1 |
| Calibration point | 1 ~ 5 o'clock |
| Use calibration fluid | 10µS / cm, 84µS / cm, 1413µS / cm, 12.88mS / cm, 111.8mS / cm |
| Temperature compensation coefficient | 0.0 ~ 10.0% / ° C |
| Temperature compensation mode | Linear or pure water |
| Conductivity cell constant | K = 0.1, 1, 10 or customized |
| Normalized temperature | 20 or 25 ° C |
| TDS | |
| Measuring range | 0 ~ 10.00, 100.0, 1000ppm, 10.00, 100.0ppt (max. 200ppt) |
| measurement accuracy | ± 1% F.S |
| display resolution | 0.01, 0.1, 1 |
| TDS conversion factor | 0.1 ~ 1.0 (default 0.5) |
| salinity | |
| Measuring range | 0.00 ~ 80.00ppt, 0.00 ~ 42.00psu |
| measurement accuracy | ± 1% F.S |
| display resolution | 0.01 |
| Measurement mode | Practical salinity (psu) or seawater salinity (ppt) |
| Resistivity | |
| Measuring range | 0.00 ~ 20.00MΩ |
| measurement accuracy | ± 1% F.S |
| display resolution | 0.01, 0.1, 1 |
| Dissolved oxygen | |
| Dissolved oxygen measurement range | 0.00 ~ 20.00mg / L |
| measurement accuracy | ± 0.2mg / L |
| display resolution | 0.1, 0.01mg / L, optional |
| % Saturation measurement range | 0.0 ~ 200.0% |
| measurement accuracy | ± 2.0% |
| display resolution | 0.1, 1% |
| Calibration point | 1 ~ 2 o'clock |
| Atmospheric pressure compensation | 60.0 ~ 112.5kPa, 450 ~ 850mmHg |
| Salinity compensation range | 0 ~ 50g / L |
| temperature | |
| Measuring range | 0 ~ 105 ° C, 32 ~ 221 ° F |
| measurement accuracy | ± 0.5 ° C |
| display resolution | 0.1 ° C, 0.1 ° F |
| Calibration point | 1 o'clock |
| Calibration range | Measured value ± 10 ° C |