Contact us For product pricing, customization, or other inquiries:
Contact Us
Explore More Products
- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
SY8000-030G-4 FREQUENCY INVERTER
-
Output Frequency:
-
0~600Hz
-
Size:
-
450MM*325MM*360MM
-
Weight:
-
31KG
-
Product name:
-
top 10 vfd manufacturer, inverter vfd, spindle vfd
-
communication:
-
RS485 modbus
-
Application:
-
oil, pump, fan
-
AI:
-
2 point 0~10V 4~20mA
-
Control:
-
VF, OPEN LOOP Vector control
-
AO:
-
1 point
-
Color:
-
Black
-
speed regulation range:
-
1:100
-
Warranty:
-
12Months
-
Speed stabilization accuracy:
-
0.5%
Quick Details
-
Output Current:
-
62.0A
-
Place of Origin:
-
Shanghai, China
-
Brand Name:
-
SANYU
-
Model Number:
-
SY8000-030G-4 FREQUENCY INVERTER
-
Output Frequency:
-
0~600Hz
-
Size:
-
450MM*325MM*360MM
-
Weight:
-
31KG
-
Product name:
-
top 10 vfd manufacturer, inverter vfd, spindle vfd
-
communication:
-
RS485 modbus
-
Application:
-
oil, pump, fan
-
AI:
-
2 point 0~10V 4~20mA
-
Control:
-
VF, OPEN LOOP Vector control
-
AO:
-
1 point
-
Color:
-
Black
-
speed regulation range:
-
1:100
-
Warranty:
-
12Months
-
Speed stabilization accuracy:
-
0.5%
Sanyu SY8000 50HZ 60HZ top 10 vfd manufacturer, inverter vfd, spindle vfd
products description
| Sanyu SY8000 50HZ 60HZ top 10 vfd manufacturer, inverter vfd, spindle vfd parameter details | ||
| Item | Spec. | |
| Input | Rated voltage: frequency | 380V or 220V: 50Hz/60Hz |
| Allowed voltage working range | Fluctuation range: :≤±1 5 %;Voltage imbalance rate:<3% | |
| Output | Rated voltage | 0~380V or 0~220V |
| Frequency | 0~600 Hz | |
| Overload capacity | Type G: 150% of rated current for 60s; 180% of rated current for 1s; 200% of rated current instant protection; | |
| Type P: 120% of rated current for 60s; 150% of rated current for 1s; 180% of rated current instant protection | ||
| Main control performance | Control mode | V/F control, Magnetic flux vector control, Non-PG current vector control |
| Modulation mode | Space voltage vector PWM modulation | |
| Speed regulation range | 1:100 (vector control without PG) | |
| Starting torque | 150% of rated torque at 2.0 Hz (Magnetic flux vector control,) | |
| 180% of rated torque at 0.5 Hz (current vector control without PG) | ||
| Speed stabilization accuracy | ≤±0.2% of rated synchronous speed | |
| Speed fluctuation | ≤±0.5% of rated synchronous speed | |
| Torque response | ≤100ms current vector control without PG | |
| Torque control | Supporting torque control under vector control mode without PG with the torque control accuracy of ±5% | |
| Resolution of input frequency | Digital setting: 0.01Hz | |
| Analog setting: Max frequency ×0.05% | ||
| Torque increase | Automatic torque increase, manual torque increase 0.1%~30.0% | |
| V/F curve | Six modes: One kind of user setting V/F curve, four kinds of decrease torque characteristic curve (2.0 power, 1.7 power, 1.5 power, 1.3 power) and linearity curve | |
| Acc/De curve | Three modes: Straight-line acceleration and decoration mode, S-curve acceleration and decoration mode, shortest acceleration and decoration mode; four kinds of acceleration and decoration time: time unit (minute/second) selected; longest time: 60 hours | |
| DC brake | DC braking frequency: 0.0Hz~max output frequency; braking time: 0.0~50.0s; braking current: 0.0%~150.0% of rated current | |
| Automatic voltage regulation (AVR) | When the network voltage makes the change, it can automatically keep the output voltage constant. | |
| Automatic current limiting | It can automatically limit current during working to prevent tripping caused by frequent over current. | |
| Voltage stall | Control the voltage during deceleration to prevent over voltage and protect stopping. | |
| Automatic carrier regulation | It can automatically regulate carrier frequency according to load characteristic and temperature characteristic; and multiple carrier modes can be selected. | |
| Wobble frequency control for spinning | Wobble frequency control for spinning can realize functions of fixed wobble frequency and change wobble frequency | |
| Frequency combination function | Running command channel and frequency setting channel can be optionally combined. | |
| Fixed length function | Length achieves stop function and the max length is 65.535 KM. | |
| Jogging control | Jogging frequency range: 0.00Hz-the Max; jogging acceleration and deceleration time: 0.1-3600.0s,jogging interval time:0.1-3600.0s | |
| Multi-speed running | Realizing multi-speed running via built-in PLC or control terminal | |
| Built-in process closed loop control | Realizing the process closed loop control system conveniently | |
| Electric quantity calculation | It can calculate electric energy consumed by electric motor to observe energy-saving effect conveniently. | |
| Running function | Running command channel | Operation panel, control terminal, serial port, external expansion setting can be shifted via various methods. |
| Frequency setting channel | Three kinds of digital settings, analog voltage setting, analog current setting, pulse setting, terminal combination setting, multi-segment speed setting and so on | |
| Auxiliary frequency setting | Realizing flexible auxiliary frequency fine regulation, frequency synthesis | |
| Impulse output terminal | 0~50kHz of impulse square signal output, it can realize physical quantity output of setting frequency, output frequency and so on. | |
| Analog output terminal | Two routes of analog signal output, output range can be flexibly set between 0~20mA or 0~10V and it can realize physical quantity output of setting frequency, output frequency and so on. | |
| LED display | Displaying sixty-one kinds of parameters of setting frequency, output frequency, output voltage and output current and the like. | |
| LCD display | NO | |
| Parameter copy | NO | |
| Option of key function | Defining function range of part keys to prevent wrongly operating | |
| Protection function | Open-phase protection (option), over-current protection, over-voltage protection, low-voltage protection, overheat protection, overload protection and off-load protection, etc. | |
| Environment | Service Location | Indoors, free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, water vapor, drip or salt, etc. |
| Altitude | Please use it by derating when it is higher than 1.000m and derated 10% per increasing 1000m. | |
| Ambient temp. | -10℃~+ 40℃(at 40℃~50℃,please use it by derating) | |
| Humidity | Less than 95% RH, no water condensation. | |
| Vibration | Less than 5.9 n/s²( 0.6g ) | |
| Storage temp. | -40℃~ +70℃ | |
| Structure | Protection level | IP20 |
| Cooling method | Wind cooling, control with fans | |
| Efficiency | 45kW and lower than 45kW≥93%;55kW and more than 55kW≥95% | |
Packaging & Shipping