Product Highlights
1. What Is Wired Glass?
- Reinforced Safety: The wire mesh holds glass fragments in place upon impact or thermal stress.
- Fire Resistance: Provides a barrier against flames and smoke spread.
- Proven Technology: A trusted solution for fire-rated and security applications for over a century.
2. How It's Manufactured
| Stage | Description |
|---|---|
| Wire Mesh Preparation | Welded steel wire mesh is cut to size and cleaned |
| Glass Forming | Molten glass is poured over and under the wire mesh simultaneously |
| Embedding | The wire mesh becomes fully encapsulated within the glass sheet |
| Polishing | Surface is fire-polished to achieve optical clarity |
| Annealing | Controlled cooling to relieve internal stresses |
Key Features & Benefits
| Feature | Benefit |
|---|---|
| Fire Resistance | Meets fire-rated requirements—prevents flame penetration and limits smoke spread (typically rated 30–60 minutes depending on configuration) |
| Impact Safety | Wire mesh holds broken glass in place—reduces risk of injury from falling shards |
| Security Glazing | Acts as a deterrent against forced entry; wire reinforcement resists cutting and break-through |
| Thermal Stability | Withstands thermal stress and sudden temperature changes better than standard annealed glass |
| Post-Breakage Integrity | Even when cracked, the glass remains intact and functional until replacement |
| Light Transmission | Provides clear visibility while maintaining safety characteristics |
Product Range
Polished Wired Glass (Clear)
| Thickness | Typical Applications |
|---|---|
| 6mm | Fire-rated doors, windows, interior partitions |
| 6.5mm – 7mm | Standard fire-rated glazing, industrial windows |
| 8mm – 10mm | High-traffic areas, security glazing, schools |
Patterned Wired Glass
| Pattern Type | Characteristics |
|---|---|
| Figured / Textured | Obscured visibility for privacy applications |
| Wired Patterned | Combines decorative texture with wire reinforcement |
Tinted Wired Glass
| Tint | Benefits |
|---|---|
| Bronze | Reduces solar heat gain; warm aesthetic |
| Gray | Reduces glare; modern appearance |
Wire Mesh Options
| Mesh Type | Description | Best Applications |
|---|---|---|
| Square Mesh | Uniform grid pattern—most common; standard for fire-rated applications | Fire doors, windows, general safety glazing |
| Hexagonal Mesh | Honeycomb pattern—enhanced visual appeal | Decorative applications, architectural features |
| Fine Mesh | Smaller wire diameter and tighter spacing—less obtrusive appearance | Retail displays, premium architectural glazing |
| Stainless Steel Mesh | Corrosion-resistant—ideal for moisture-prone environments | Bathrooms, coastal applications, industrial facilities |
Applications
| Sector | Common Uses |
|---|---|
| Fire-Rated Glazing | Fire doors, fire-resistant windows, emergency exit doors, stairwell enclosures |
| Educational Facilities | School windows, gymnasium glazing, corridor partitions—where impact safety is required |
| Industrial | Factory windows, machinery enclosures, warehouse glazing |
| Commercial | Storefronts, office partitions, security glazing |
| Residential | Garage windows, basement windows, skylights, bathroom windows |
| Public Buildings | Hospitals, government buildings, transportation terminals |
| Walkways & Roofs | Pedestrian walkways, skylights, canopies (where fall protection is required) |
Fire Ratings & Compliance
| Rating | Performance | Typical Configuration |
|---|---|---|
| 30-Minute Fire Rating | Withstands fire for 30 minutes without flame penetration | 6mm–7mm wired glass |
| 60-Minute Fire Rating | Extended protection for higher-risk applications | 8mm–10mm wired glass or wired glass in steel frames |
| Smoke Control | Prevents smoke passage through glazed openings | All wired glass configurations |
Safety Standards & Certifications
| Standard | Compliance |
|---|---|
| EN 572 | European float glass standard (wired glass variant) |
| ASTM E119 | Fire resistance testing standard |
| ANSI Z97.1 | Impact safety requirements |
| CPSC 16 CFR 1201 | Consumer product safety glazing standards |
| Local Building Codes | Meets fire safety and impact glazing requirements in most jurisdictions |
Technical Specifications
| Property | Value |
|---|---|
| Density | ~2500 kg/m³ |
| Light Transmission (Clear 6mm) | 75–80% (wire mesh reduces transmission slightly vs. standard glass) |
| Fire Resistance | Typically 30–60 minutes (varies by thickness and framing) |
| Impact Resistance | Maintains integrity after breakage; wire retains fragments |
| Maximum Size | Up to 2134mm × 3300mm (varies by thickness) |
| Thickness Tolerance | ±0.3mm |
Comparison: Wired Glass vs. Alternatives
| Feature | Wired Glass | Tempered Glass | Laminated Glass |
|---|---|---|---|
| Fire Resistance | Excellent—inherent fire-rated properties | Limited—may shatter under thermal stress | Limited—interlayer may degrade under fire |
| Impact Safety | Fragments retained by wire mesh | Shatters into small granules | Fragments adhere to interlayer |
| Security | Wire resists cutting and breakthrough | Moderate—shatters upon impact | High—interlayer holds fragments |
| Cost | Economical | Moderate | Higher |
| Aesthetics | Visible wire pattern | Clear, unobstructed | Clear, unobstructed |
| Post-Breakage | Remains intact and functional | Loses integrity completely | Remains intact but may sag |
| Fabrication | Cannot be tempered or laminated after production | Can be further processed | Can be further processed |
Limitations & Considerations
| Consideration | Details |
|---|---|
| Surface Quality | Polished wired glass may have slight surface irregularities due to manufacturing process |
| Fabrication Restrictions | Cannot be tempered, heat-strengthened, or cut after production—must be ordered to final size |
| Edge Exposure | Cut edges expose wire mesh; edges should be protected or framed |
| Visual Distraction | Wire pattern is visible and may be considered aesthetic or obstructive depending on application |
| Moisture Exposure | Standard mild steel mesh may rust if edges are exposed to moisture—use stainless steel mesh for high-humidity environments |
Quality Assurance
- Wire Mesh Integrity: Continuous inspection ensures wire mesh is properly positioned and fully encapsulated
- Optical Quality: Fire-polished surface with minimal distortion
- Edge Finishing: Clean cuts with protected edges to prevent moisture ingress
- Thickness Consistency: Uniform thickness for consistent framing and installation
- Packaging: Interleaving paper and edge protection to prevent scratching
Why Choose Our Wired Glass
- Proven Reliability: Manufactured using traditional, time-tested methods with modern quality controls
- Comprehensive Range: Clear, patterned, tinted—multiple thicknesses and mesh configurations
- Fire Safety Focus: Engineered to meet rigorous fire-rated requirements
- Competitive Pricing: Economical solution for fire and impact safety applications
- Global Supply: Trusted by architects, contractors, and facility managers worldwide
- Technical Support: Expert guidance on fire ratings, code compliance, and installation requirements